Rain Master Irrigation Systems DX2 User Manual
Chapter 10: Troubleshooting Page 215
Refer to (A-22)
Disconnect the EV-CAB-SEN wires from the flow sensor
Red & Black wires.
Is there +8.0 VDC measured at
Inputs 1+ and 1- terminals?
Is there +8.0 VDC measured at the
white & black EV-CAB-SEN
wires?
No
Yes
Yes
5
6
7
8
Insure all water is off
Drain line (relieve pressure)
A
Consult Factory
Refer to (A-22)
Re-connect sensor wires from “Input 1+” and
“Input 1-“ terminals.
9
B
EV-CAB-SEN is defective. See
Appendix G for measuring continuity.
No