www.evolutionbuild.com
19
When all adjustments, settings or maintenance
have been completed, make sure that all keys
or wrenches have been removed, and that all
screws, bolts and other fittings are securely
tightened.
While the machine has been factory set, it is
advisable that the 0
0
setting of the rotary table
and the 90
0
perpendicular setting of the tilt
head be checked, as these positions may have
moved in transit.
To confirm the 0
0
rotary table setting:
a) Set the rotary table at 0
0
and tighten the
rotary table lock handle.
b) Use an engineers square (not supplied) to
check that the angle between the machines
fence guide and the blade is 90
0
. (Fig. 24)
c) If the angle requires adjustment, loosen
the four fence guide clamp screws and align
the fence guide against the engineers square.
Retighten the clamp screws.
Similarly check that the angle of the saw blade
to the face of the table is 90
0
. (Fig. 25)
To adjust:
a) Loosen the locknut
b) Using a suitable allen key screw the 90
0
adjustment screw clockwise or counter
clockwise until correct alignment has been
achieved. (Fig. 26)
c) Retighten the locknut.
The 45
0
bevel setting can also be adjusted.
a) Set the cutting head to 45
0
and check the
angle between the blade and the machine
table with a 45
0
set square (not provided).
b) To adjust, loosen the 45
0
adjusting screw
locknut and using a suitable allen key turn the
adjusting screw clockwise or anti- clockwise
until the correct alignment is achieved. (Fig. 27)
c) Retighten the locknut.
PLUG REPLACEMENT
The fuse in the main plug of your power
tool should always be replaced with one of
identical rating.
Check the voltage given on your power tool
matches the supply voltage.
The power tool is supplied with a fitted plug,
however if you should need to fit a new plug
follows the instruction below.
IMPORTANT
The wire in the mains lead are coloured in
accordance with the following code:
Blue ---Neutral
Brown ---Live
Green/Yellow --- Earth
The wire that is coloured blue must be
connected to the terminal that is marked
with the letter N. The wire that is coloured
brown must be connected to the terminal
that is marked with the letter L. The wire that
is coloured green/yellow must be connected
to the terminal that is marked with the letter
E.
A 13AMP (BS1363 or BS1363/A) plug must
be used and a 5 AMP fuse must be fitted.
ENVIRONMENTAL PROTECTION
Waste electrical products should not be
disposed of with household waste. Please
recycle where facilities exist. Check with
your Local Authority or retailer for recycling
advice.
RAGE 6
Comentarios a estos manuales